| **Expedited Plan Checks** - we continue to offer expedited Tenant Improvement Plan Check Review. Applicants who have plans submitted to the Building Division for plan check may request an expedited review. But hurry, this offer is based on availability and is first come, first served. To find out how, click here. Current codes applicable to all projects include: - 2010 California Building Code (CBC) with City of Roseville Amendments, based on the 2009 IBC
- 2010 California Residential Code (CRC) with Appendix H, Patio Covers, based on the 2009 IRC
- 2010 California Historical Building Code (CHBC)
- 2010 California Existing Building Code (CEBC), based on the 2009 IEBC
- 2010 California Green Buildings Standards Code (CGBSC)
- 2010 California Fire Code (CFC), based on the 2009 IFC, with City of Roseville Amendments (RFC)
- 2010 California Mechanical Code (CMC), based on the 2009 UMC
- 2010 California Plumbing Code (CPC), based on the 2009 UPC
- 2010 California Electrical Code (CEC) with City of Roseville Amendments, based on the 2008 NEC
- 2010 California Energy Code (CEC)
- 2009 Uniform Swimming Pool, Spa, and Hot Tub Code (USPSHTC), as published by IAPMO
SPECIAL NOTES: #1. Effective January 01, 2011, all residential permits exceeding $1000 in valuation will require smoke & carbon monoxide detectors throughout the residence, to be inspected and verified at final inspection. Smoke & carbon monoxide detectors must be installed in accordance with (click here) CRC Section R314.6.2 and R315.2. Effective March 1, 2011, all permits installed by contractors or others will be assessed a valuation exceeding $1000 and therefore subject to this requirement. Should you have any questions, please contact the Building Official at gpaolini@roseville.ca.us. #2. Effective January 01, 2011, the City of Roseville has adopted the 2010 California Green Building Code. For further information regarding Green Code requirements, click here. SNOW LOADS: Ground Snow Load - Zero WIND LOADS: Basic Wind Speed: 3-Second Gust - 85 mph, Fastest Mile - 71 mph; Exposure Category B (most areas) RAIN LOADS: 3" per hour EARTHQUAKE LOADS: Seismic Design Category for all structures and components shall be SDC-D except as follows: - All low rise conventional framed structures, maximum three (3) stories in height, shall be permitted to be designed using SDC C for site soil class D or better.
- All permanently attached nonstructural components with importance factor, lp, = 1.0 shall be permitted to be designed/installed using SDC C.
SOIL BEARING PRESSURE: - Allowable Foundation - 1500 psf without a soils report.
- Allowable lateral - 100 psf/ft without a soils report.
CLIMATE ZONE: 11(most areas), Zone 12 where justified by the California Energy Commission mapping. SANITARY FACILITIES: 2010 CPC Chapter 4, Table 4-1 and Table A. Plan check typically takes approximately 3 weeks for first review, and 2 weeks for subsequent reviews. Permits can usually be issued over the counter for re-roofs, heating and air conditioning replacements, replacement of water lines, gas lines, water heaters, addition to existing electrical system and electrical service upgrades. Although a contractor will often secure permits, it is the responsibility of the homeowner to make sure all necessary permits are obtained. Building permits are also required for mechanical, electrical and plumbing projects or replacements. The Plan Check Index contains links to PDF documents that may be of interest to you. Back to Top Plan Check Index Commercial Request Plan Copies Plan Copy Packet Third Party Plan Check Review 3rd Party Plan Check Review Policy Certificate of Occupancy Requirements C of O New Commercial Projects New Commercial Plan Review Process New Commercial Plan Check Submittal Temporary Power Pole Requirements New Commercial Fee Schedule Transportation Systems Management (TSM) Application - This program applies to all businesses or common work location (such as office buildings/complexes, commercial/retail centers, or industrial buildings/parks) with 50 or more employees. The City's TSM requirements are located in Chapter 11.33 of the Roseville Municipal Code. Solar Energy Photovoltaic (PV) Non-Residential PV Packet Tenant Improvement Projects Tenant Improvement Procedure Tenant Improvement Information Required Tenant Improvement Design Requirements Tenant Improvement Packet - Includes the Building Permit Application, Construction Comment Form, CUPA Form, Air Quality Worksheet, and Asbestos Declaration. The Worksheet for Accessibility Requirements must also be submitted with this packet. Transportation Systems Management (TSM) Application - This program applies to all businesses or common work location (such as office buildings/complexes, commercial/retail centers, or industrial buildings/parks) with 50 or more employees. The City's TSM requirements are located in Chapter 11.33 of the Roseville Municipal Code. Non-Residential HVAC Replacement Submittal Checklist Residential Carports/Detached Sheds over 120 SF Requirements for carports & detached sheds Electric Service Upgrade/Service Panel Relocation Residential Service Upgrade and Panel Relocation Procedure Electric Service Entrance Requirements Service Entrance Conduit Installation Electric and Gas Meters at One Location Electric Load Worksheet Energy Compliance Re-Roof Cool Roof Requirements Certificate of Compliance: CF-1R for Window Replacement Certificate of Compliance: CF-1R for Water Heater Energy Form/Residential Additions = or less than 100sf Energy Form/Residential Additions = or less than 1000sf Energy Form/Residential Additions greater than 1000sf Energy Form for New Residential Buildings, Package D New Residential Energy Standards, Effective 01/01/2010 Energy Standards, Indoor & Mechanical Ventilation HVAC Requirements Kitchen Lighting Worksheet Mandatory Measures Checklist: Residential MF-1R Form Residential Solar Energy Photovoltaic (PV) Packet Non Electric Solar Panel Requirements for SFD Pool & Water Heating Fire Sprinklers Residential Fire Sprinkler Submittal Requirements Garage Conversions Interior Remodeling Checklist Gas Line Replacement/Addition/Equipment Gas Piping Information - Includes the Gas Piping Information Sheet, Table 12-1 of the 2010 California Plumbing Code, and the New Gas Piping Schematic forms. Gas Test Procedure Gas and Electric Meters at One Location In-Ground Pools and Spas Swimming Pool Packet - Includes the Permit Checklist, Pool Requirements, Plumbing/Mechanical/Energy Requirements, Enclosure & Fencing Requirements, Electrical Requirements, Electrical Load Worksheet, Alarm Requirements, Acknowledgement, Access Agreement, and Notice to Pool Contractors forms. Installing a Free-Standing Fireplace, Fireplace/Woodstove Insert, or permanent Gas BBQ Exterior Freestanding Concrete/Masonry Fireplace and Fire Pit Installations Permanent Exterior Gas BBQ Patio Covers Patio Cover Permit Requirements ICC Patio Cover Permit Checklist Example Patio Cover Construction Detail Production Home Builders Residential Master Plan Policy New Master Plan Submittal Requirements Model Home Complex Application Residential Submittal Comment Form Temporary Sales Trailer Application Raised Decks (+30" above ground) Sample Deck Drawings Sample Plot Plan Raised Deck & Guardrail Requirements Remodeling Existing Dwelling Interior Remodeling Checklist New Mechanical Units in Attic or on Top of Roof for an Existing Structure Residential Care Facilities (R3.1) Requirements Residential Care Facilities Checklist Typical Construction Detail Retaining Walls Retaining Wall Permit Requirements Sample Engineering Detail of a Retaining Wall Room Addition Residential Addition Submittal Requirements Example Plot Plan Typical Construction Detail Fees for Single Family Dwelling Addition Electric Load Worksheet Single Family Dwelling Single Family Dwelling Submittal Requirements Sewage Ejector Systems Smoke & Carbon Monoxide Detectors Smoke & Carbon Monoxide Alarm Requirements CRC Section R314.6.2 and R315.2 Back to Top | Public Works - Building Inspection 311 Vernon Street (916) 774-5332 (916) 774-5394 Fax (916) 774-5220 TDD buildingdivision@roseville.ca.us |